What you need

  • The bed level: the lowest ground in the tank. Here 29.300.
  • The water spread at each contour: the area enclosed by each contour inside the tank, measured from the contour plan. Here every 0.25 m:
Level Water spread (m²)
29.50 420
29.75 1,180
30.00 2,050
30.25 2,980
30.50 3,890
  • The FTL: the full tank level, here 30.25.

Step 1: from the bed to the first contour

Below the first contour the water is a shallow dish that narrows to nothing at the bed. Treat it as a cone: V = A × h ÷ 3, with A the area of the first contour and h its height above the bed.

V = 420 × (29.50 − 29.30) ÷ 3 = 28.00 m³

Step 2: each step by the average end area

Between two contours h apart, with areas A₁ and A₂: V = h × (A₁ + A₂) ÷ 2. The capacity at each level is the running total.

From To Volume of the step (m³) Capacity (m³) Capacity (ML)
29.30 (bed) 29.50 28.00 28.00 0.028
29.50 29.75 0.25 × (420 + 1,180) ÷ 2 = 200.00 228.00 0.228
29.75 30.00 0.25 × (1,180 + 2,050) ÷ 2 = 403.75 631.75 0.632
30.00 30.25 0.25 × (2,050 + 2,980) ÷ 2 = 628.75 1,260.50 1.261
30.25 30.50 0.25 × (2,980 + 3,890) ÷ 2 = 858.75 2,119.25 2.119

At the FTL of 30.25 the tank holds 1,260.50 m³ (1.26 ML) over 2,980 m² of water. One megalitre is 1,000 m³.

Step 3: check by the prismoidal formula

The prismoidal formula (Simpson’s rule) takes the contours two steps at a time, using the middle contour’s real area: V = h ÷ 3 × (A₁ + 4 A₂ + A₃), with h the 0.25 m step.

  • 29.50 to 30.00: 0.25 ÷ 3 × (420 + 4 × 1,180 + 2,050) = 599.17 m³
  • 30.00 to 30.50: 0.25 ÷ 3 × (2,050 + 4 × 2,980 + 3,890) = 1,488.33 m³

So the capacity at 30.00 is 28.00 + 599.17 = 627.17 m³, and at 30.50 it is 2,115.50 m³. The average end area gives 2,119.25 m³: 0.18% more. The prismoidal formula needs an even number of steps.

Step 4: draw the area–capacity curve

Plot the levels up the side. Along the foot, plot the capacity at each level and join the points with a solid line. Along the top, on its own scale, plot the water spread and join it with a dashed line. Draw the FTL across.

From the curve you can read the capacity and the water spread at any level, and the level for any capacity: for this tank, a capacity of 1,000 m³ is reached at about 30.15.

Where the average end area over-estimates

The average end area takes the water between two contours as a shape whose area changes evenly. In a tank, whose sides slope inward, the real shape is closer to part of a cone or pyramid, and the rule gives too much.

Take a tank shaped like an upside-down pyramid, 40 m square at the top and 4 m deep. The water spread 2 m above the bed is 400 m², and 3 m above the bed it is 900 m².

  • Average end area: 1 × (400 + 900) ÷ 2 = 650.00 m³
  • The true volume of that slice of the pyramid: 633.33 m³
  • So the average end area is 2.6% high for that one step.

The prismoidal formula, with the area at 2.5 m (625 m²), gives 1 ÷ 6 × (400 + 4 × 625 + 900) = 633.33 m³, exact here because the pyramid’s sides are straight. On real ground neither rule is exact; the closer the contours, the smaller the error.

Things to watch

  • The spill level. Water rises only to the lowest point on the bund or the tank’s rim. A capacity above that level is not real: the water would run out there. Check the FTL against the lowest point of the bund.
  • Measure inside the tank only. A separate hollow, such as a borrow pit behind the bund, is not part of the tank’s capacity even if it is below the FTL.
  • Desilting. The capacity table is for the bed as surveyed. A desilting quantity is the volume between the present bed and the design bed, worked out separately.

The water spread at each level comes from the contour plan: see how to draw contours from total station data. For the average end area and prismoidal formulas on a route, see earthwork volume by the average end area method.